Data Options and Profiles
Setting Options: Changing Your Active
Profile, pA
To change the option values in the active profile (pA), use the set command.
The program command cannot be used to change options in pA.
To change an option value in pA, at the CMD: prompt type:
set option to value
For example:
set echo to on
set text to diagnostic
NOTE:
Values in pA are not automatically stored. Unless you only want to
temporarily change options, it is important to save any changes by copying
pA to one of the stored profiles. In the event of a power failure, pA values
are overwritten by values in p1.
To store pA, at the CMD: prompt type:
copy pA to p1
or, for example,
copy pA to p4
NOTE:
In all of the above procedures, the word ‘‘to’’ is optional. Examples of the
command without ‘‘to’’ are:
set echo on
set text diagnostic